Air Velocity Transmitter

SERIES EE65

Features :

Low Angular Dependence
Easy Installation
Adjustable To Application Requirements
Range : 0 to 10 / 15 / 20 m/s
Out put : 0 to 10V / 4 to 20 mA
Temp. Range : 0 to 50 Deg C

Applications

HVAC and Clean Room Monitoring
Monitoring Incoming and Outgoing Air (energy Management) In HVAC Applications
Filter Monitoring And Laminar Flow Control In Cleanrooms
Exhaust Systems, Exhaust Hoods And Glove Boxes In The Pharmaceutical,
Bio and Semiconductor Industries
Mass Flow Measurement During Incineration Processes
Monitoring and Measurement Of Compressed Air Systems
Air Conveying Systems
Wind Tunnels and Climate Simulators

SERIES EE66

Features :

Measurement Down To 0 m/s
Low Angular Dependence
Easy Installation
Range : 0 to 1 /1.5 / 2 m/s
Out put : 0 to 10V / 4 to 20 mA
Temp. Range : 0 to 50 Deg C

Applications

HVAC and Clean Room Monitoring
Monitoring Incoming and Outgoing Air (energy Management) In HVAC Applications
Filter Monitoring And Laminar Flow Control In Cleanrooms
Exhaust Systems, Exhaust Hoods And Glove Boxes In The Pharmaceutical,
Bio and Semiconductor Industries
Mass Flow Measurement During Incineration Processes
Monitoring and Measurement Of Compressed Air Systems
Air Conveying Systems
Wind Tunnels and Climate Simulators

SERIES EE75

Features :

High Accuracy
Working Range 0…40 m/s (0…8000ft/min) and -40…120°c (-40…248°f)
Measurement Of Air Velocity and Temperature Calculation Of Volumetric Flow Rate
Low Dependence Of Angle Of Inflow
Probe Diameter 8mm (0.3″)
Remote Probe Up To 10m (32.8ft)
Easy Mounting and Maintenance
Correction For Pressure, Humidity and Media
Low Flow Cut-off
SI and US Units Selectable

Applications

HVAC and Clean Room Monitoring
Monitoring Incoming and Outgoing Air (energy Management) In HVAC Applications
Filter Monitoring And Laminar Flow Control In Cleanrooms
Exhaust Systems, Exhaust Hoods And Glove Boxes In The Pharmaceutical,
Bio and Semiconductor Industries
Mass Flow Measurement During Incineration Processes
Monitoring and Measurement Of Compressed Air Systems
Air Conveying Systems
Wind Tunnels and Climate Simulators

AIR VELOCITY & TEMPERATURE TRANSMITTER

MODEL CTV 100

Features :

Temperature and air velocity transmitter type CTV100.
Ranges from 0-5 m/s to 0-30 m/s and 0 to +500 C, -20 to +800 C, -50 to +500 C, 0 to +1000 C
0-10 V or 4-20 mA output, active, power supply 24 Vac/Vdc (3-4 wires)
ABS IP 65 housing, with or without display
Alternating display pf air velocity and temperature
Quick and easy mounting “1/4 turm” system with wall-mount plate

Applications

Filter Status
Duct Static Pressure
Clean Room Pressure
Building Pressure
Fan and Blower Pressure
Paint Booths
Dust Collectors
Glove Box Pressure
Bubbler Systems
Laminar Flow Hoods
Cabinet Purging

AIR VELOCITY & TEMPERATURE TRANSMITTER

MODEL CTV 100

Features :

Function : airflow
Simultaneous display of 2 parameters
2 output 4-20 mA or 0-10 V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
2 visual (dual color LED) and audible (buzzer) alarms
Software or DIP switch configuration
ABS – IP 65 housing, with or without 2-line backlit display
Mounting with the 1/4 turn system with wall-mount plate

Series VTP

Features :

Media: Air and compatible, non combustible gases
Velocity: Min. 0 to 200 FPM (0-1 m/s) Max.
0 to 4000 FPM (0-20 m/s)
Pressure: Min 0 to 0.1″ w.c. (0-25 Pa) Max. 0 to 10″ w.c. (0-3 kPa)
Temperature: 14 to 122° F (-10 to 50° C) or optional -4 to 257° F (-20 to 125° C)
Accuracy: 3% F.S. optional 1% F.S. Pressure: 1% F.S.
Temperature: +/- 1.8° F (1° C)
Output: Independent 4-20 mA output for air velocity, temperature, and optional pressure

Applications

Filter Status
Duct Static Pressure
Clean Room Pressure
Building Pressure
Fan and Blower Pressure
Paint Booths
Dust Collectors
Glove Box Pressure
Bubbler Systems
Laminar Flow Hoods
Cabinet Purging